CodeCalc 2009 - Build Summary Initial release - January 1st 2009 Latest Build - June 10th 2009 *********************************************************** CodeCalc Build, CC_2009_090610, June 10th, 2009 *********************************************************** Corrections : -------------- *) Fixed an issue related to nozzle on head outside the 80% limit. The program was using the Joint efficiency of the head seam. (conservative error). *) Added the Vessel-nozzle MDMT for each material. *) Accounted for Impact tested materials in the Shells, Nozzles and Flange modules. *) Program was incorrectly printing the ambient rating instead of oprating flange rating in the summary of the small Nozzles. *) Fixed an issue in the Pipe and Pad summary. *) Tema Tubesheet - Added output enhancements - calculation change for differential pressure design (program was conservative). *) Fixed some performance issues. *) Fixed the look up of the structural steel shapes for vessel legs. Enhancements : -------------- 1. Implemented separate lookup table for Young's modulus and Coeff. of thermal Expansion. 2. Added the option for user to specity tr/t ratio to reduce req. tubesheet extension thickness in TEMA tubesheet module. 3. Added the treatment of "Q" type nozzle weld type. 4. Updated the ASME material databases to include more information *********************************************************** CodeCalc Build, CC_2009_090101, January 1st, 2009 *********************************************************** Corrections: ----------- *) General - corrected a timing issue esecially when the the computer is slow or the program is run across a network. *) Flange - corrected the req. thickness for non-circular blind flange. CodeCalc was conservative. *) Fixed an issue with merging shell in to the WRC 297/Annex G module. *) British Tubesheet - Added one tube dia. to the Outer tube limit diameter variable, program was taking it as the distance between outer tube centers. *) Pipe-pad - Fixed the y value for Temperature > 1150F. *) Fixed an issue that affected the hillside nozzle calculation. *) Added 22in nominal pipe size Note: Refer to the Readme.doc in the program Root directory for the 2009 new feature list.